DR 1900 PORTABLE SPECTROPHOTOMETER

DR1900 PORTABLE SPECTROPHOTOMETER HACH


The DR1900 excels in the field because it is the lightest and most compact portable spectrophotometer. Your field testing takes you to potentially dusty and wet conditions where other equipment simply won’t be safe. The DR1900 is built for rugged conditions, and it’s flexible, --accepting the widest range of vial sizes. Built with field use in mind, the DR1900 has a large, clear screen and a simple user interface that makes testing easier than ever in even the most demanding conditions. Easy to hold, and operate, the compact DR1900 is a valuable tool for your field technicians.
Underneath the rugged exterior, the DR1900 has the largest number,-- over 220-- of the most commonly tested preprogrammed methods already built in. You can also use the easy-to-use interface to create your own methods. Tests are performed with a wavelength range of 340 to 800 nm which make this a field instrument you can use to find results typically only seen in laboratory instruments.
Please note: TNTplus vial test evaluation possible, but without barcode identification & 10 fold measurement and outlier elimination.

Specifications
Operating Mode Transmittance (%), Absorbance and Concentration
Source Lamp Xenon Flash
Wavelength Range 340 to 800 nm
Wavelength Accuracy ± 2 nm (range 340 - 800nm)
Wavelength Selection Automatic
Wavelength Reproducibility ± 0.1 nm
Spectral bandwidth 5 nm
Photometric Measuring Range 0 to 3 Abs (wavelength range 340 – 800 nm)
Photometric Accuracy ± 0.003 Abs @ 0.0 - 0.5 Abs
Photometric Linearity < 0.5 % (0.5 - 2.0 Abs)
Stray Light < 0.5% T@340nm with NaNO2
Display Graphical display 240 x 160 pixel (LCD, b/w, backlit)
Data Logger 500 measured values
Preprogrammed Methods > 220
User Programs 50
Sample Cell Compatibility 13 / 16 mm and 1 inch round
adapter, 1 inch square and 10x10mm
Dimensions (H x W x D) 3.9 in x 7 in x 10.5 in
(98 mm x 178 mm x 267 mm)
Weight 3.31 lbs. (1.5 kg)
Operating Conditions 10 to 40 °C (50 - 104 °F),
max. 80 % relative humidity
(non-condensing)
Storage Conditions -30 to 60 °C (-22 to 140 °F), max.
80 % relative humidity (non-condensing)
Enclosure Rating IP67
ADDRESS
Rukan Mitra Matraman Blok B - 12
Jl. Matraman Raya No. 148 Jakarta 13150
TELEPHONE
(021) 859 181 54, (021) 859 181 55, (021) 859 023 91, (021) 851 259 5
HANDPHONE
0813 988 55242, 0877 811 22777, 0812 864 04835, 0812 863 8194
FAX
(021) 859 181 78
EMAIL
1. sales@octaprimalestari.com 2. e_anasthasia@octaprimalestari.com, 3. meliati_layarda@octaprimalestari.com 4. octaprima_lestari@yahoo.com
Copyright © 2016 - PT Octa Prima Lestari,
Jasa Pembuatan Website by IKT