TL2300 Tungsten Lamp Turbidimeter, EPA, 0 - 4000 NTU

TL2300 Tungsten Lamp Turbidimeter, EPA, 0 - 4000 NTU Hach
LPV444.99.00210

Specifications
Accuracy: Ratio on: ±2% of reading plus 0.01 NTU from 0 - 1000 NTU, ±5% of
reading from 1000 - 4000 NTU based on formazin primary standard
Ratio off: ±2% of reading plus 0.01 NTU from 0 - 40 NTU
Air purge: Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975)
0.05 L/s at 69 kPa (10 psig); 138 kPa (20 psig) max
Hose barb connection for 1/8-inch tubing
Certifications: CE, KC, RCM
Communication: USB
Compliance: EPA
Data logging: 2000 total logs, includes reading log, verification log and calibration log
Dimensions (H x W x D): 153 mm x 395 mm x 305 mm
Display: 17.8 mm colour touch screen
Interface: 2 USB-A ports for USB flash drive, external thermal printer, keyboard
and barcode scanner
Light source: Tungsten filament lamp
Measurement method: Nephelometric
Model: TL2300 EPA
Operating temperature range: 0 - 40 °C
Power requirements (Amps): 3.4 A
Power requirements (Hz): 50/60 Hz
Power requirements (Voltage): 100 - 240 VAC
Range: 0 - 4000 NTU
NTU (Ratio on): 0 - 4000
NTU (Ratio off): 0 - 40
EBC (Ratio on): 0 - 980
EBC (Ratio off): 0 - 9.8
Reading modes: Single, continuous, Rapidly Settling Turbidity, signal averaging
on or off, ratio on or off
Regulatory: Meets EPA Method 180.1
Repeatability: ±1% of reading or 0.01 NTU, whichever is greater
(under reference conditions)
Response Time: Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds
(when 10 measurements are used to calculate the average)
Sample cell compatibility: Round cells 95 x 25 mm (3.74 x 1 in.)
borosilicate glass with rubber-lined screw caps
Note: Smaller sample cells (less than 25 mm) can be used when a cell
adapter is used.
Sample requirements: 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F)
Source Lamp: Tungsten Lamp
Stabilisation time: Ratio on: 30 minutes after start-up
Ratio off: 60 minutes after start-up
Storage conditions: -20 to 60 °C
Units: NTU and EBC
Weight: 3.0 kg
What's included?:
TL2300 Turbidimeter, silicone oil, oiling cloth, USEPA filter assembly, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover
ADDRESS
Rukan Mitra Matraman Blok B - 12
Jl. Matraman Raya No. 148 Jakarta 13150
TELEPHONE
(021) 859 181 54, (021) 859 181 55, (021) 859 023 91, (021) 851 259 5
HANDPHONE
0813 988 55242, 0877 811 22777, 0812 864 04835, 0812 863 8194
FAX
(021) 859 181 78
EMAIL
1. sales@octaprimalestari.com 2. e_anasthasia@octaprimalestari.com, 3. meliati_layarda@octaprimalestari.com 4. octaprima_lestari@yahoo.com
Copyright © 2016 - PT Octa Prima Lestari,
Jasa Pembuatan Website by IKT