Logo

FLASH POINT CLOSED CUP TESTER KOEHLER INST

FLASH POINT CLOSED CUP TESTER

K16273 PENSKY MARTENS CLOSED CUP FLASH TESTER

TEST METHOD :
For flash point determination of fuels, lubricating oils, liquids containing
suspended solids and liquids that tend to form a surface film during testing.


Specifications :
• Conforms to ASTM D93 and related
• Choice of electric or gas heating . Determines flash points of a wide range of
products by a closed cup method with two option speed stirring of the sample.

Extensively used in shipping and safety regulations for detection of contamination
by volatile and flammable materials in fuel oils and lubricating oils, and for
characterization of hazardous waste samples.
Smooth operating cover mechanism slides shutter open and applies test flame at
the turn of a knob.
Cover fits over brass test cup and includes pilot flame, test flame reference bead,
built-in stirrer and plated brass thermometer ferrule.
Electrically heated model is equipped with a 1000W nickel-chromium heater with stepless variable control for accurate, repeatable temperature rate of rise settings
per specifications.
Heater unit is enclosed in a stainless steel housing with cooling vents. Includes line
cord receptacle and switch for accessory slow speed stirrer.
Gas heated model has a built-in nickel plated brass natural gas burner, or can be supplied with an artificial gas burner or liquid propane burner.

Both models are mounted on a sturdy cast iron base.
• Dimensions lxwxh :24 x 20 x 57 cm (with optional stirrer motor installed)
• Weight : 10.6 Kg

Conforms to the specifications of:
ASTM D93; AASHTO T73-811; IP 34; ISO 2719; DIN 51758; FTM 791-1102;
NF M 07-019

Electrical Requirements:
220-240V 50/60Hz, Single Phase, 3.4A

INCLUDED ACCESSORIES
Brass Test Cup with Handle
Thermometer Holder
Cover Assembly

STIRRER MOTOR
• Two speed operation
• Mounts in base of Pensky-Martens tester
Slow speed gear motor with twin pulley rotates stirrer of Pensky-Martens Closed
Cup Flash Tester at 115 RPM for the basic procedure or at 250 RPM for
suspensions of solids and highly viscous samples.
Chuck accepts flexible stirrer shaft of flash tester.
• Includes :
adjustable support bracket and mounting rod with threaded end for easy
installation in base of K16203/K16273 or K16000 flash tester, and
three-conductor line cord and plug.

More From FLASH POINT CLOSED CUP TESTER

ADDRESS
Rukan Mitra Matraman Blok B - 12
Jl. Matraman Raya No. 148 Jakarta 13150
TELEPHONE
(021) 859 181 54, (021) 859 181 55, (021) 859 023 91, (021) 851 259 5
HANDPHONE
0813 988 55242, 0877 811 22777, 0812 864 04835, 0812 863 8194
FAX
(021) 859 181 78
EMAIL
1. sales@octaprimalestari.com 2. e_anasthasia@octaprimalestari.com, 3. meliati_layarda@octaprimalestari.com 4. octaprima_lestari@yahoo.com
Copyright © 2016 - PT Octa Prima Lestari,
Jasa Pembuatan Website by IKT